SINGLE CRYSTAL XRD Available for Booking
  • Specifications:

    Sealed tube X-ray sources

    • Mo radiation 

    Microfocus TXS Rotating Anode

    • Compact Direct drive with low maintenance
    • Pre-crystallized and pre-aligned filaments
    • IµS 3.0 microfocus X-ray source - tailored to the needs of crystallography
    • Mo  radiation
    • Twice the intensity of conventional microfocus sources
    • Air-cooled

    Advanced safety enclosures

    • Compliant with the strictest radiation safety regulations
    • Compliant with the new machinery directive

    Goniometer

    • FIXED-CHI
    • KAPPA
    • Best goniometer precision
    • Sphere of confusion of less than 7 micrometer ensures that even your smallest sample stays reliably in the center of the X-ray beam.
    •  
    • Software
    • APEX3 is the most complete suite for chemical crystallography
    • PROTEUM3 now with a data processing pipeline for structural biology
    • Fully integrated low temperature devices (Oxford Cryosystem: Cobraplus)

    Intelligent Goniometer Control - 3D robotic path planning

    Within the concept of DAVINCI.DESIGN the D8 VENTURE use a revolutionary 3D robotic path planning algorithm to efficiently drive the goniometer, maximizing the system’s capabilities. The path planning software continuously checks the validity of the experimental setup. Hardware recognition identifies components like mirrors, collimators or beam stops automatically.

    The intelligent beam path components store all important information about functionality, spatial requirements and dependencies with other components in a memory chip.

    Adding the knowledge about the current position of each component provides an up-to-date 3D model of the system and allows the dynamic calculation of an efficient and safe goniometer driving path:

    • Adding or removing a component from the system is instantly updated in the instrument status and available for automated software path planning.
  • Charges & Payment Details for SC-XRD

    Experiments

    Internal users

    External Academic users(Rs) with GST 18% Extra

    Industry users(Rs) with GST 18% Extra

    Phd/Project student(Rs)

    Consultancy

    Crystal Screening

    Rs 100

    Rs 150

    Rs 1000

    Rs 2500

    Full Data Collection including Crystal Screening

    Rs 500

    Rs 750

    Rs 4000

    Rs 8000

    Data collection at low temperature

    Rs 1000

    Rs 1500

    Rs 5000

    Rs 10000

    For Chemistry department, each extensive user faculty is required to submit Rs. 20,000 annually per equipment. You are also required to submit the payment details to CRF office.

    ** For External Users

    • Additionally, 18% GST is applicable for TBIF and External Users as per GOI norms
    • Payment can be made through any mode to this account number such as NEFT/RTGS/UPI payment gateways/QR scanner

     

     Bank Details for transfer of sample Analysis charges

              

    Name of Institute

    Indian Institute of Technology

    Name of the Institute

    Account holder/Designation

    Registrar, IIT Ropar

    Bank Account Name

    IIT Ropar Revenue Account

    Type of bank

    Account

    Saving Account

    Complete Account

    Number

    37360100716

    RTGS/IFSC code of

    the Branch

    SBIN0013181

    MICR Code

    140002008

    Name of Bank

    State Bank of India

    UPI ID

    theregistrar716@sbi

                                                                                                           

    • Checklist to be submitted:
      • Completely filled and signed Job Requisition Form
      • Duly prepared Samples (or mention if preparation is reqd.)
      • Self-addressed envelope with appropriate postal stamps (if invoice is reqd. by post)
      • Proof of payment with transaction
  • Faculty Incharge:
     
     Dr Debaprasad Mandal
      Asso.Prof
    Phone: 1881-232051
    Email: dmandal@iitrpr.ac.in

     Operator: 

    Name:Kamlesh Satpute

    Email::-scxrdadmin@iitrpr.ac.in

    Ph. No.- 1881-233053