LSCM Available for Booking
  • Specifications

    1 Microscope

    • Inverted stand: Axio Observer

    • Upright stand: Axio Examiner, Axio Imager

    • Port for coupling of ELYRA

    • Camera port

    • Manual or motorized stages

    • Incubation solutions

    • Fast Z piezo inserts

    • Definite Focus

    2 Objectives

    • C-APOCHROMAT

    • Plan-APOCHROMAT

    • W Plan-APOCHROMAT, Clr Plan-APOCHROMAT, Clr Plan-NEOFLUAR

    • LCI Plan-APOCHROMAT

    3 Illumination

    • UV laser: 355 nm, 405 nm

    • VIS laser: 440 nm, 458 nm, 488 nm, 514 nm, 543 nm, 561 nm, 594 nm, 633 nm

    • NIR laser for multiphoton imaging: Ti:Sa, OPO*, InSight DeepSee*, Discovery*

    4 Detection

    • 3 or 34 descanned spectral channels

    (GaAsP and/or multialkali PMT)

    • Airyscan detector with optional Fast module

    • 2 additional GaAsP channels (BiG.2)

    • Up to 6 non-descanned GaAsP detectors

    • Up to 12 non-descanned GaAsP or PMT detectors total

    • Transmitted light detector (T-PMT)

    5 Software

    • ZEN, recommended modules:

    Tiles & Positions, Experiment Designer, FRAP, FRET, RICS, FCS, Deconvolution, 3Dxl Viewer – powered by arivis

     

    Scanning Module

    Scanner Two independent, galvanometric scanning mirrors with ultrashort line and frame flyback

    Scanning Resolution 4 × 1 to 8192 × 8192 pixels, also for multiple channels, continuously adjustable

    Scanning Speed 19 × 2 speed levels; up to 13 images/sec. with 512 × 512 pixels (max. 430 images/sec. 512 × 16), up to 6875 lines/sec.

    In Fast Airyscan mode: 13×2 speed levels, up to 19 images/sec. with 512×512 (max. 27 images/sec. 480×480, or 6 images/sec. 1024×1024)

    Scanning Zoom 0.6 × to 40 ×; digitally adjustable in increments of 0.1 (Axio Examiner: 0.67 × to 40 ×)

    Scanning Rotation Can be rotated freely (360 degrees), adjustable in increments of one degree, freely adjustable XY offset

    Scanning Field 20 mm field diagonal (max. 18 mm for Axio Examiner) in the intermediate image plane, with full pupil illumination

    Pinholes Master pinhole with preset size and position; can be adjusted as desired for multitracking and short wavelengths (such as 405 nm)

    Beam Path Exchangeable Twin Gate beam splitter with up to 100 combinations of excitation wavelengths and outstanding laser line suppression;

    manual interface port for external detection modules (such as BiG.2, Airyscan, third party detectors, internal detection

    with spectral signal separation and signal recycling loop for compensation of polarization effects)

    Detection Options

    Detectors 3 or 34 spectral detection channels, GaAsP and /or multialkali PMT (QE 45% typical for GaAsP)

    2 additional GaAsP detection channels (BiG.2)

    Airyscan detector (32 channels GaAsP), delivers resolution up to 140 nm lateral, 400 nm axial; in Fast mode: 145/180 nm lateral, 450 nm axial

    Up to 12 non-descanned detection channels (PMT and/or GaAsP)

    Transmitted light detector (PMT)

    Spectral Detection 3 or 34 simultaneous, confocal reflected-light channels, GaAsP and /or PMT based

    freely adjustable spectral detection area (resolution down to 3 nm)

    Data Depth 8 bit, 12 bit or 16 bit available; up to 35 channels simultaneously detectable

    Real-Time Electronics Microscope, laser, scanning module and additional accessory control; data acquisition and synchronization management through real-time

    electronics; oversampling read-out logic; ability to evaluate data online during image acquisition

     

    ZEN Imaging Software

    System Configurations Workspace to conveniently configure all of the motorized functions of the scanning module, laser and microscope; save and restore application configurations (Re-use)

    System Self Rest Calibration and testing tool to automatically test and calibrate the system

    Recording Modes, Smart Setup: Spot, Line/Spline, Frame, Tiles, Z Stack, Lambda Stack, Time Series and all combinations (XYZ, lambda, t), online calculation and visualization of ratio images, average and summation (by line/image, adjustable), Step Scan (for higher image frame rates);

    quick set up of imaging conditions using Smart Setup by simply selecting the labelling dye

    Crop Function Easily select scanning areas (simultaneously select zoom, offset, rotation)

    Real ROI Scan, Spline Scan: Scans of up to 99 designated ROIs (regions of interest) as desired and pixel-by-pixel laser blanking; scan along a freely defined line

    ROI Bleaching Localized bleaching in up to 99 bleach ROIs for applications such as FRAP (fluorescence recovery after photobleaching) or uncaging; use of different speeds for bleaching and imaging, use of different laser lines for different ROIs

    Multitracking Rapidly change excitation lines when recording multiple fluorescences for the purpose of minimizing signal crosstalk and increasing dynamic range

    Fast Acquisition Fast mode scan with 4x parallelisation in Y-direction, detection by Airyscan module

    Lambda Scan Parallel or sequential acquisition of image stacks with spectral information for every pixel

    Linear Unmixing Acquisition of crosstalk-free, multiple fluorescence images using simultaneous excitation; online or offline and automatic or interactive unmixing; advanced unmixing logic with indication of reliability

    Visualization XY, orthogonal (XY, XZ, YZ), Cut (3D section); 2.5D for time series of line scans, projections (maximum intensity); animations;

    Depth coding (inverse colors), brightness, gamma and contrast settings; color table selection and modification (LUT), character functions

    Image Analysis and Operations : Colocalization and histogram analysis with individual parameters, number & brightness analysis, profile measurement along user-defined lines, measurement of lengths, angles, areas, intensities and much more; operations: addition, subtraction, multiplication, division, ratio, shift, filters (low-pass, median, high-pass, etc., also user-definable)

    Image Management Features for managing images and the corresponding imaging parameters; multiprint feature; streaming of acquisition data for online processing of large data sets

    Applications

    Live cell imaging, FRET, FRAP, Co-localisation analysis, Spectral Mixing, 3D Recontruction

  • Charges & Payment Details for LSCM

    Experiments:

    Each slot is of 2 hours

    Internal Users

    External Academic Users

    (Rs) With GST 18% Extra

    Industry Users

    (Rs) With GST 18% Extra

    Phd/Project Student (Rs)

    Consultancy work (Rs)

    Confocal Microscope

    250

    500

    1500

    4000

    Live Cell Imaging

    (for 24 hours)

    1000

    2000

    6000

    16000

    ** For External Users

    • Additionally, 18% GST is applicable for TBIF and External Users as per GOI norms
    • Payment can be made through any mode to this account number such as NEFT/RTGS/UPI payment gateways/QR scanner

     

    Bank Details for transfer of sample Analysis charges

    Name of Institute

    Indian Institute of Technology

    Name of the Institute Account

    holder/Designation

    Registrar, IIT Ropar

    Bank Account Name

    IIT Ropar Revenue Account

    Type of bank

    Account

    Saving Account

    Complete Account

    Number

    37360100716

    RTGS/IFSC code of

    the Branch

    SBIN0013181

    MICR Code

    140002008

    Name of Bank

    State Bank of India

    UPI ID

    theregistrar716@sbi

              


    • Checklist to be submitted:
      • Completely filled and signed Job Requisition Form
      • Duly prepared Samples (or mention if preparation is reqd.)
      • Self-addressed envelope with appropriate postal stamps (if invoice is reqd. by post)
      • Proof of payment with transaction details

     

  • Image Gallery
  • Faculty Incharge:-

    Name:Dr Durba Pal

    Asst.Prof

    Phone: 01881-232506

    Email: durba.pal@iitrpr.ac.in

    Operator: 

    Name:Mr. Farooq Ahmed

    Phone–01881-23-2556

    Email Id:-crf.lscm@iitrpr.ac.in